Summary

In Brocade Fabric OS before 9.2.2d and 10.0.0 through 10.0.0a1, handling of specific download protocols uses unsanitized parameter strings. When processing upgrade requests, parameters are converted into system command strings and executed via a shell. Because control characters and shell metacharacters are not stripped, an attacker can execute arbitrary shell commands with the firmware management daemon's elevated privileges.

Risk Assessment

Potential for remote code execution with elevated privileges, leading to full compromise of the switch and SAN.

Recommendation

Upgrade Brocade Fabric OS to 9.2.2d or later (or 10.0.0a2+). Restrict access to upgrade functions and apply input filtering.

Other vulnerabilities in Brocade Fabric OS

See all
Original NVD description (English source)

Brocade Fabric versions before 9.2.2d and 10.0.0 through 10.0.0a1 handling of specific download protocols utilizes unsanitized parameter strings. When processing upgrade requests, parameters are converted into system command strings and executed through a system shell interface. Because control characters and shell metacharacters in fields like the host or file path are not stripped or sanitized, an attacker can execute arbitrary shell commands with the firmware management daemon's elevated privileges.