CVE-2026-5574
MediumCVSS 6.5Exploitation Probability (EPSS)
Low risk42th percentile - higher than 42% of all known CVEs
Summary
Missing authorization in the deletefile function of the FsBrowseClean component in Technostrobe HI-LED-WR120-G2 (version 5.5.0.1R6.03.30). Manipulation of the dir/path argument allows remote file deletion.
Risk Assessment
A remote attacker can delete arbitrary files on the system, potentially leading to data loss or device instability.
Recommendation
Contact the vendor for a patch; temporarily restrict access to the device.
Other vulnerabilities in Technostrobe HI-LED-WR120-G2
See all- CVE-2026-5573High
A weakness has been identified in Technostrobe HI-LED-WR120-G2 version 5.5.0.1R6.03.30 in an unknown function of the file /fs. Manipulating the argument cwd can lead to unrestricted upload. The attack can be launched remotely. The exploit has been made public and could be used for attacks.
- CVE-2026-5572Medium
Technostrobe HI-LED-WR120-G2 version 5.5.0.1R6.03.30 is vulnerable to CSRF in an unknown function. The attack can be performed remotely, and the exploit has been publicly released.
- CVE-2026-5571Medium
Technostrobe HI-LED-WR120-G2 version 5.5.0.1R6.03.30 has a vulnerability in an unknown function of the /fs file in the Configuration Data Handler component. Manipulating the File argument leads to information disclosure. The attack is remote, and the exploit is public. The vendor did not respond.
- CVE-2026-5570High
Technostrobe HI-LED-WR120-G2 version 5.5.0.1R6.03.30 has a vulnerability in the index_config function of the /LoginCB file, causing improper authentication. The attack can be performed remotely, and the exploit is publicly available.
- CVE-2026-5569High
The Technostrobe HI-LED-WR120-G2 device version 5.5.0.1R6.03.30 has a vulnerability in an unknown function of the /Technostrobe/ endpoint. Manipulation leads to improper access controls. The attack can be performed remotely, and the exploit has been made public. The vendor did not respond.
Original NVD description (English source)
A security vulnerability has been detected in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. Affected is the function deletefile of the component FsBrowseClean. The manipulation of the argument dir/path leads to missing authorization. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Vulnerability data from NVD (NIST) · CISA KEV · EPSS