CVE-2026-16438
CriticalCVSS 9.4Summary
Mitsubishi Electric products (GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, MobileHMI, MC Works64) versions 10.97.3 and prior contain an incorrect privilege assignment vulnerability. Installers grant default DCOM permissions to the administrator account, allowing an attacker to locally or remotely launch and operate DCOM objects that should require UAC elevation.
Risk Assessment
The vulnerability could lead to disclosure, tampering, destruction, or deletion of internal information, or cause a denial-of-service (DoS) condition. Organizations using these products are exposed to attacks using the administrator account.
Recommendation
Update products to the latest versions or apply vendor patches. Restrict DCOM permissions for the administrator account and monitor unusual DCOM activity.
Related vulnerabilities
- CVE-2026-109694Critical
The Fluent CRM plugin (up to 3.2.5) contains an incorrect privilege assignment vulnerability that allows privilege escalation. An attacker could exploit this flaw to gain higher privileges within the WordPress system.
- CVE-2026-108497Critical
The Amelia Booking plugin (up to 2.4.10) contains an SQL Injection vulnerability due to improper neutralization of special elements in SQL commands. An attacker could execute arbitrary SQL queries, potentially leading to data leakage or modification.
- CVE-2026-50619Critical
A path traversal vulnerability has been reported in Qsirch, which could allow remote attackers to read unexpected files or system data. The vulnerability has been fixed in version 7.0.3.0 and later.
- CVE-2026-50612Critical
A Unix symbolic link (symlink) following vulnerability has been reported in QuMagie. If a remote attacker gains a user account, they can exploit the vulnerability to compromise the security of the system. The vulnerability has been fixed in version 2.9.2 and later.
- CVE-2026-47786Critical
An OS command injection vulnerability has been reported in HybridDesk Station, which could allow remote attackers to execute arbitrary commands. The vulnerability has been fixed in versions 4.2.23 and 4.3.4 and later.
- CVE-2026-34006Critical
A missing authentication for critical function vulnerability has been reported in sMedio DTCP MOVE, which could allow remote attackers to gain access to the system. The vulnerability has been fixed in version 1.4.5 and later.
- CVE-2026-19863Critical
In EthereumAuthenticator, an unauthenticated client may access certain protected resources if the request path contains the configured login path. This is caused by the authenticator using an unanchored substring match when identifying the login page, which may replace authentication or role requirements with ALLOWED.
- CVE-2026-16436Critical
Mitsubishi Electric products (GENESIS, GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, MobileHMI, IoTWorX, MC Works64, GENESIS32, BizViz) contain a weak password recovery mechanism for forgotten passwords. The challenge response used to unlock the system is common to all users and fixed, allowing a remote attacker to unlock the system after obtaining it.
- CVE-2026-102469Critical
The Vert.x DB2 client (vertx-db2-client) deserializes User Defined Type (UDT) column data using a bare ObjectInputStream.readObject() call without an ObjectInputFilter or class allowlist. A malicious or man-in-the-middle DRDA server can send a response with a column tagged as UDT (FDOCA LID 0x50), causing deserialization of attacker-controlled bytes. TLS is disabled by default, making man-in-the-middle exploitation feasible.
- CVE-2026-101287Critical
Authentication bypass vulnerability in Stela versions prior to 1.60.1 due to the use of a cookie named “authProcess” without validating its integrity. The application stores the user identifier (userId) and the status of the authentication process (validSteps) in this cookie and relies on these client-modifiable values to complete the login process.
Original NVD description (English source)
Incorrect Privilege Assignment vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, ICONICS Suite versions 10.97.3 and prior, Hyper Historian versions 10.97.3 and prior, AnalytiX versions 10.97.3 and prior, MobileHMI 10.97.3 and prior, MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, ICONICS Suite versions 10.97.3 and prior, Hyper Historian versions 10.97.3 and prior, AnalytiX versions 10.97.3 and prior, and MobileHMI 10.97.3 and prior allows an attacker who can log in using the same administrator account for the affected products to launch and operate DCOM objects locally or remotely. During installation, the installers of the affected products unnecessarily grant default DCOM permissions to the administrator account of the affected products. Users with that administrator accounts can locally or remotely launch and operate DCOM objects that should require UAC elevation. As a result, the attacker may disclose, tamper with, destroy, or delete internal information, or cause the affected system to enter a denial-of-service (DoS) condition.
Vulnerability data from NVD (NIST) · CISA KEV · EPSS

