Summary

ImprintLab Medical-SAM-Adapter 0.1.0-alpha/0.1.0 contains a vulnerability in the session.get_modelmeta.custom_metadata_map function in models/MobileSAMv2/ultralytics/nn/autobackend.py. Manipulation of the imgsz/names/kpt_shape arguments leads to improper neutralization of directives in dynamically evaluated code, requiring local access. The exploit is publicly available.

Risk Assessment

A local attacker can use the public exploit to execute arbitrary code. This may lead to full system compromise.

Recommendation

Immediately apply available mitigations or restrict access to the application. Monitor the project for a patch.

Related vulnerabilities

Original NVD description (English source)

A security flaw has been discovered in ImprintLab Medical-SAM-Adapter 0.1.0-alpha/0.1.0. Affected by this issue is the function session.get_modelmeta.custom_metadata_map of the file models/MobileSAMv2/ultralytics/nn/autobackend.py of the component AutoBackend Model Loading. The manipulation of the argument imgsz/names/kpt_shape results in improper neutralization of directives in dynamically evaluated code. The attack requires a local approach. The exploit has been released to the public and may be used for attacks. The project was informed of the problem early through an issue report but has not responded yet.