CVE Catalog

CVE-2025-5946

HighCVSS 7.2
Published: Updated: Translated: NVD NIST

Exploitation Probability (EPSS)

Very high risk
13.51%

96th percentile - higher than 96% of all known CVEs

Summary

OS Command Injection vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules). On the poller parameters page, a user with high privilege can concatenate custom instructions into the poller reload command.

Risk Assessment

A user with high privileges can execute arbitrary commands on the server, potentially leading to full compromise of the monitoring system.

Recommendation

Upgrade to version 24.10.13, 24.04.18, or 23.10.28 or later, which contain the fix.

Other vulnerabilities in Centreon Infra Monitoring

See all
Original NVD description (English source)

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.

Vulnerability data from NVD (NIST) · CISA KEV · EPSS