Summary

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 has an insufficient authentication issue. The camera does not enforce authentication to /cgi-bin/param.cgi when requests lack an HTTP Authorization header. A remote unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configuration details, and can also update configuration values or overwrite the whole file.

Risk Assessment

An attacker can obtain credentials and modify camera configuration, potentially leading to privacy breaches and compromise of the surveillance system.

Recommendation

Update the camera firmware to version 6.3.40 or later.

Related vulnerabilities

Original NVD description (English source)

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.