CVE-2023-40801
HighCVSS 8.8Exploitation Probability (EPSS)
Low risk50th percentile - higher than 50% of all known CVEs
Summary
The sub_451784 function does not validate the parameters entered by the user, resulting in a stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn.
Risk Assessment
This vulnerability may allow attackers to execute remote code or destabilize the system, posing a serious threat to the security of the device and network.
Recommendation
It is recommended to update the device firmware to the latest version that includes security patches addressing this vulnerability.
Other vulnerabilities in Tenda AC23 v16.03.07.45_cn
See all- CVE-2026-1420High
A flaw has been found in Tenda AC23 16.03.07.52. It impacts an unknown function of the file /goform/WifiExtraSet. Manipulation of the argument wpapsk_crypto causes buffer overflow. Remote exploitation is possible, and the exploit has been published and may be used.
- CVE-2026-0640High
A vulnerability has been identified in Tenda AC23 firmware version 16.03.07.52, affecting the sscanf function in the /goform/PowerSaveSet file. Manipulation of the Time argument can lead to a buffer overflow. The attack can be launched remotely, and the exploit is publicly available.
- CVE-2023-40799Critical
Tenda AC23 version Vv16.03.07.45_cn is vulnerable to buffer overflow in the sub_450A4C function.
- CVE-2022-32386Critical
A buffer overflow vulnerability was discovered in the Tenda AC23 router firmware version v16.03.07.44 in the fromAdvSetMacMtuWan function. An attacker could exploit this flaw to execute arbitrary code or cause a denial of service.
- CVE-2022-32385Critical
A stack overflow vulnerability was discovered in the Tenda AC23 router running firmware version v16.03.07.44. This allows a remote attacker to execute arbitrary code on the device.
- CVE-2023-40798High
In Tenda AC23 v16.03.07.45_cn, the formSetIPv6status and formGetWanParameter functions do not authenticate user input parameters, resulting in a post-authentication stack overflow vulnerability.
- CVE-2023-40797High
In Tenda AC23 v16.03.07.45_cn, the sub_4781A4 function does not validate the parameters entered by the user, resulting in a post-authentication stack overflow vulnerability.
- CVE-2023-40802Medium
The get_parentControl_list_Info function does not verify the parameters entered by the user, leading to a post-authentication heap overflow vulnerability in Tenda AC23 v16.03.07.45_cn.
- CVE-2023-40800High
The compare_parentcontrol_time function does not authenticate user input parameters, resulting in a post-authentication stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn.
- CVE-2022-32384High
A stack overflow vulnerability was discovered in Tenda AC23 router firmware v16.03.07.44. It occurs in the formWifiBasicSet function via the security_5g parameter.
Original NVD description (English source)
The sub_451784 function does not validate the parameters entered by the user, resulting in a stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn