CVE-2023-38936
CriticalCVSS 9.8Exploitation Probability (EPSS)
Low risk49th percentile - higher than 49% of all known CVEs
Summary
Tenda AC10, AC1206, AC6, AC7, AC5, FH1203, AC9, and FH1205 devices were found to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
Risk Assessment
An attacker could exploit this vulnerability to execute malicious code, potentially leading to device takeover.
Recommendation
It is recommended to update the device firmware to the latest version to mitigate this vulnerability.
Related vulnerabilities
- CVE-2026-97785Critical
Improper authentication in AAD App Proxy allows an unauthorized attacker to elevate privileges over a network.
- CVE-2026-83938Critical
Missing authentication for a critical function in Azure Kubernetes Configuration Service allows an unauthorized attacker to elevate privileges over a network.
- CVE-2026-110063Critical
Improper link resolution before file access ('link following') in VM Inspector for Azure Virtual Machines allows an unauthorized attacker to elevate privileges over a network.
- CVE-2026-109122Critical
The network management service on affected Kiloview E3 NDI encoder firmware fails to sanitize one field used when configuring static routes via the web management API. An authenticated web user with permission to configure static routes can exploit this to execute arbitrary operating system commands as root, and the malicious configuration persists across reboots.
- CVE-2026-105014Critical
Improper neutralization of special elements used in a command ('command injection') in Azure Pipelines allows an unauthorized attacker to execute code over a network.
- CVE-2026-114625Critical
VeloCloud Orchestrator (VCO) on-prem has a security issue that may allow a remote attacker to access privileged internal functionality and impact the VCO host. Any authenticated user can gain operator privileges and masquerade as a local "superuser operator" user, accessing functionality intended for internal use only and not meant to be remotely accessible.
- CVE-2026-79876Critical
No vulnerability description was provided in the supplied NVD data. Technical details and the affected component cannot be determined from the available information.
- CVE-2026-79875Critical
No vulnerability description was provided in the supplied NVD data. Technical details and the affected component cannot be determined from the available information.
- CVE-2026-79874Critical
No vulnerability description was provided in the supplied NVD data. Technical details and the affected component cannot be determined from the available information.
- CVE-2026-79873Critical
No vulnerability description was provided in the supplied NVD data. Technical details and the affected component cannot be determined from the available information.
Original NVD description (English source)
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
Vulnerability data from NVD (NIST) · CISA KEV · EPSS

