Summary

A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to cause the system to consume additional memory, eventually forcing the device to restart. The issue is due to insufficient rate-limiting protection.

Risk Assessment

An attacker could exploit this vulnerability to cause a temporary denial of service (DoS), impacting the availability of the system within the organization. The device restart after memory exhaustion may lead to service interruptions.

Recommendation

It is recommended to update the software to IoT-FND Release 4.0 or later to mitigate this vulnerability. Additionally, implementing monitoring and throttling mechanisms for TCP traffic on open ports is advisable.

Related vulnerabilities

Original NVD description (English source)

A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to cause the system to consume additional memory, eventually forcing the device to restart, aka Memory Exhaustion. The vulnerability is due to insufficient rate-limiting protection. An attacker could exploit this vulnerability by sending a high rate of TCP packets to a specific group of open listening ports on a targeted device. An exploit could allow the attacker to cause the system to consume additional memory. If enough available memory is consumed, the system will restart, creating a temporary denial of service (DoS) condition. The DoS condition will end after the device has finished the restart process. This vulnerability affects the following Cisco products: Connected Grid Network Management System, if running a software release prior to IoT-FND Release 4.0; IoT Field Network Director, if running a software release prior to IoT-FND Release 4

Vulnerability data from NVD (NIST) · CISA KEV · EPSS