CVE Vulnerability Catalog
Translated CVE descriptions from NVD NIST - in English
CISA KEV catalog updated: (v2026.07.29)
A vulnerability in the Java SE component of Oracle Java SE (subcomponent: JavaFX) allows an unauthenticated attacker with network access to compromise Java SE. Successful attacks require human interaction and may significantly impact additional products.
A vulnerability was discovered in Siemens SiPass integrated (all versions before V2.70) that could allow an attacker with network access to bypass the authentication mechanism and perform administrative operations.
A vulnerability was discovered in Siemens ViewPort for Web Office Portal before revision number 1453 that could allow an unauthenticated remote user to upload arbitrary code and execute it with the permissions of the operating-system user running the web server by sending specially crafted network packets to port 443/TCP or port 80/TCP.
Crypto-NAK packets in ntpd in NTP versions 4.2.x before 4.2.8p4 and 4.3.x before 4.3.77 allow remote attackers to bypass authentication.
The datalen parameter in the refclock driver in NTP 4.2.x before 4.2.8p4 and 4.3.x before 4.3.77 allows remote attackers to execute arbitrary code or cause a denial of service (crash) via a negative input value.
The rate limiting feature in NTP versions 4.x before 4.2.8p4 and 4.3.x before 4.3.77 is vulnerable. Remote attackers can exploit this vulnerability by sending a large number of crafted requests.
The NSSCipherSuite option with ciphersuites enabled in mod_nss before version 1.0.12 allows remote attackers to bypass application restrictions.
The Loginizer plugin before version 1.3.6 for WordPress has an SQL Injection vulnerability that can be exploited via the X-Forwarded-For HTTP header.
Zend/Session/SessionManager in Zend Framework 2.2.x before 2.2.9 and 2.3.x before 2.3.4 allows remote attackers to create valid sessions without using session validators.
SQL injection vulnerability exists in Quest KACE Asset Management Appliance versions 6.4.120822 through 7.2 and Systems Management Appliance versions 6.4.120822 through 7.2.101.
The api/storage web interface in Unitrends Backup (UB) before version 10.0.0 has an issue with the validation of one of its input parameters. A remote attacker could exploit this flaw to bypass authentication and execute arbitrary commands with root privileges on the target system.
A vulnerability was discovered in the bpserverd protocol in Unitrends Backup (UB) before version 10.0.0, allowing authentication to be bypassed. A remote attacker could exploit this issue to execute arbitrary commands with root privileges on the target system.
A Missing Encryption of Sensitive Data issue was discovered in PDQ Manufacturing LaserWash G5, G5 S Series, M5, 360, 360 Plus, AutoXpress, AutoExpress Plus, LaserJet, ProTouch Tandem, ProTouch ICON, and ProTouch AutoGloss. The username and password are transmitted insecurely.
An Improper Authentication issue was discovered in PDQ Manufacturing LaserWash G5, G5 S Series, M5, 360, 360 Plus, AutoXpress, AutoExpress Plus, and ProTouch systems. The web server does not properly verify that provided authentication information is correct.
An Improper Access Control issue was discovered in Schweitzer Engineering Laboratories (SEL) SEL-3620 and SEL-3622 Security Gateway Versions R202, R203, R203-V1, R203-V2, R204, and R204-V1. The device does not properly enforce access control while configured for NAT port forwarding, which may allow for unauthorized communications to downstream devices.
A vulnerability in the authentication module of Cisco Identity Services Engine (ISE) could allow an unauthenticated, remote attacker to bypass local authentication. The issue is due to improper handling of authentication requests and policy assignment for externally authenticated users.
The zmq3 input and output modules in rsyslog before version 8.28.0 interpreted description fields as format strings, potentially allowing a format string attack with unspecified impact.
An issue was discovered in SMA Solar Technology products related to the SIP implementation, which does not properly use authentication with encryption. This makes it vulnerable to replay attacks, packet injection attacks, and man in the middle attacks.
An issue was discovered in SMA Solar Technology products that allows an attacker to update device firmware without authentication using the SMAdata2+ protocol or Sunny Explorer. If an attacker creates a custom firmware version accepted by the inverter, it can be completely compromised.
An issue was discovered in SMA Solar Technology products related to the use of a weak hashing algorithm for encrypting passwords in REGISTER requests. This algorithm can be cracked relatively easily, allowing an attacker to gain access to passwords.

