Edimax BR-6478AC vulnerabilities
11 known CVE vulnerabilities in Edimax BR-6478AC, translated and rated.
- CVE-2026-10166Medium
Edimax BR-6478AC router version 1.23 has a command injection vulnerability in the formWlbasic function. Manipulating the rootAPmac argument allows remote command execution. The exploit is public.
- CVE-2026-10165High
A stack-based buffer overflow was identified in Edimax BR-6478AC version 1.23 in the formWanTcpipSetup function of the /goform/formWanTcpipSetup file. The attack can be launched remotely, and the exploit is publicly available.
- CVE-2026-10164High
A vulnerability was found in Edimax BR-6478AC 1.23. The function formUSBFolder of the file /goform/formUSBFolder is affected by buffer overflow via manipulation of the ShareName/SelectName arguments, allowing remote exploitation.
- CVE-2026-10163High
A vulnerability has been found in Edimax BR-6478AC 1.23. The function formUSBAccount of the file /goform/formUSBAccount is affected by buffer overflow via manipulation of the UserName/Password arguments, allowing remote exploitation.
- CVE-2026-10127Medium
In Edimax BR-6478AC 1.23, the formStaDrvSetup function in /goform/formStaDrvSetup is vulnerable to command injection via the rootAPmac argument. The attack can be performed remotely, and the exploit is publicly available.
- CVE-2026-10126High
Buffer overflow in the formQoS function of Edimax BR-6478AC 1.23 allows a remote attacker to execute code by manipulating the selSSID argument.
- CVE-2026-10125High
In Edimax BR-6478AC version 1.23, a stack-based buffer overflow vulnerability was found in the formPPPoESetup function of the /goform/formPPPoESetup file. The attack involves manipulating the pppUserName argument and can be performed remotely. The exploit is publicly available.
- CVE-2026-9443High
Buffer overflow vulnerability in the formL2TPSetup function in /goform/formL2TPSetup on Edimax BR-6478AC 1.23. Manipulating the L2TPUserName argument can lead to buffer overflow.
- CVE-2026-9442High
Buffer overflow vulnerability in the formiNICSiteSurvey function in /goform/formiNICSiteSurvey on Edimax BR-6478AC 1.23. Manipulating the selSSID argument can lead to buffer overflow.
- CVE-2026-9441Medium
A vulnerability in Edimax BR-6478AC 1.23. The formiNICbasic function in /goform/formiNICbasic of the POST Request Handler component allows command injection via the rootAPmac argument. Remote attack, exploit public.
- CVE-2026-9440Medium
A vulnerability in Edimax BR-6478AC 1.23. The formAccept function in /goform/formAccept of the POST Request Handler component allows command injection via the submit-url argument. Remote attack possible, exploit public.